29 Jun 463: Exchanger
Steady state heat transfer, linear static stress, and linear buckling analysis of an exchanger design. The maximum allowable stress values for the static stress analysis were taken from standard ASME Section II D, which the model passed, although the recommendation was made to include environmental loads such as wind to ensure the design was strong enough for operation and to pass the required standards.