29 Jun 051: Separation Tower
Modal, response spectrum analysis (RSA), and a linear static stress analysis of a separation tower, using a plate element model. One design was analysed, with multiple static stress load cases considered, including environmental loads such as wind loads which were calculated by FEA-Solutions. For the modal analysis, the modes and the mass participations were reported. For the RSA and stress analyses, the maximum stress within the assembly was reported.